If your machine is running with less power as before, or if the spark is visible through the vents , very possibly :
- The carbon brush is worn out. Solution: Change the carbon brushes with spare brushes.
- The armature may burnt partially. Solution: Change the armature.
- The gear worn out(no spark is visible). Solution: Change the gear set or armature.
Return the machines to the authorized service center to inspect and repair.